Oil temperature sensors for r-series speed-reducing machines and electric generators

2022-11-09 14:28:29 阅读

A fuel temperature sensor set of r-seriesreducing machines and electric generators. A flow switch with two contact points in the r series ofreducing machines and electric generators installed in the pressure line downstream of the oil cooler at the export point of the system will serve as an additional monitoring instrument. When the r-seriesreducing machine is well-prescribed, the gear-suspending agency enters the motor. thermometers that are necessary for the r series ofreducing machines and an electrical set of contact functions, as mentioned in the following section (for reconciliation values, see technical data tables) are shown in theMotor-gear reducerA set of oil temperatures from the collectors. Each contact switch must have two contact points and can also be used for remote temperature indications. During this time delay, all lubricating points in the r-seriesreducing machines will be supplied with fresh oil, while at lower ambient temperatures, cool oil from gear agencies will be mixed with hot oil from the collector tanks. If the first point of contact is not manipulated and the amount of oil does not reach a low value, the point of contact sends a signal of a safe stop. When the radial bearing reaches a high acceptable temperature, the r seriesreducing gears enter the motor. It is important to note that a lubricating oil system will be possible only if the oil levels are above a specified mark and the oil temperature reaches a low acceptable temperature. When the alarm signal is raised, the reasons for the oil temperature alarm need to be identified as soon as possible. After an additional five hours of alarm signals, the failure points need to be identified and, if they are not found, the gear agency will have to manually intercept the motor. In addition, a set of four resistance thermometers (list no. Np21) installed in specially designed run-off bearings by r-seriesreducing machines and electric generators were used as temperature monitoring. The following section refers to contact functions that are necessary (for the reconciliation values, see technical data tables) when the oil temperature sensor is measured to a low temperature of three minutes, the r series ofreducing machines and electric generators are activated to maintain the wheel-back pump and to open the high-pressure oil pump. in one scenario, when the specified low oil quantity is not reached, series rGeared motorThe component input motor will be disconnected. the correspondingreducing r series and electrical sets of sensors and corresponding contact switches are not included in the supply range。

R series decelerator.jpg

When it reaches high oil temperatures, send a warning signal. An alarm signal was sent when the r seriesreducing machine and the electric power set reached high oil temperatures. The r series decelerator contact switch must have four contact points, and can also be used for a set of long-range temperature indications for r series slowters and generators. if the oil level drops below a specific markMotor gearedAn electrical set installed at the bottom of the shell of the gear unit, which is designed as the oil spot control instrument in the tank, will send a warning signal. The second contact point is used in an emergency. When the alarm signal is raised, the reasons for the oil temperature alarm need to be identified as soon as possible. In the case of auto-managing, the locked valve limit switch is used to release the pump. By comparing the temperature of the r series ofreducing machines at two locations, it is possible to calculate the value of the r series ofreducing machines and a set of electric chillers for the reduction of the temperature (for temperature values, see technical data tables). The r seriesreducing machine measure sensors and the corresponding contact switches are not included in the supply range. After an additional five hours of alarm signals, the failure points need to be identified and, if they are not found, the gear agency will have to manually intercept the motor. The cooler's downward oil temperature is indicated by the thermometer at the export point of the r-seriesreducing oil route system. Note: during the normal operation of the oil-routing system, i. E. , the r-seriesreducing system must be opened for all stop-valves in the direction of the pressure table and the pressure switch in the controlled position. Start r-seriesreducing filter pollution monitoring. In the case of cold oil, the generality of alarm signals may be due to increasing power loss in filters protected by this contact point. installed inHorizontal reducera resistance thermometer downstream of the oil cooler at the export point of the electrical circuit system was used to transmit key data on the measured. by a further 10 minutes, the signal is sent through the intermission relay to open the input motor. during normal operation, the stop-valve may be temporarily removed from the position (to check and replace a certain instrument or instrument). (for reconciliation values, see technical data tables). http://boserlgearreducer.com/product/list-rxiliijiansuji-cn.html


Keywords: Bevel Gear Reducer Selection_Hardened Gear Surface Reducer Motor Selection_Helical Gear Reducer Selection_Bevel Gear Reducer Selection_Worm Gear Servo Motor and Reducer Selection


标签:  Oil temperature sensors for speed-reducing machines

Documentation related to this product / Related DownLoad

Product Document Name Click to download
Specimen download for speed-reducing machines Click to download
CONTACT

Contact us

Guangdong Boshi Transmission Technology Co., Ltd.

Contact: Mr. Zhang

Mobile: +86 13360667204 (also WeChat ID)

Email: [email protected]

Address: Xiedi Industrial Zone, Wanjiang District, Dongguan City, Guangdong Province

ATTENTION

ATTENTION

Copyrights©2018 Guangdong Boshi Transmission Technology Co., Ltd. All Rights Reserved Powered by MetInfo 7.1.0©2008-2025MetInfo Inc.